Home > Product > Plug & Socket Test Equipment > RH-5014 Glow Wire Test Apparatus IEC 60695-2-10-2013~IE C60695-2-13(GB/T 5169.10~13)
 
 

Product Name:RH-5014 Glow Wire Test Apparatus IEC 60695-2-10-2013~IE C60695-2-13(GB/T 5169.10~13)

Product category:Plug & Socket Test Equipment

Product Description

RH-5014 Glow Wire Test Apparatus


Application
Insulating materials in electrical equipment need to resist ignition from thermal stresses induced by non-flaming glowing sources, for short periods. The performance of the internal materials cannot affect the fire safety of equipment. Glow Wire Test Apparatus using electricity heating regulation material (Ni80 / Cr20) of resistance wire (Φ 4 mm Ni-Cr alloy wire) to 550 ℃~ 960 ℃ in 1 min, then with 1.0 N vertically burn it 30s, measure the fire risk by product light-off or hold burning time, also test light-off degree, light-off temperature (GWIT; IEC 60695-2-13), flammability and combustible index (GWFI; IEC 60695-2-12). GWFI is the highest temperature which satisfies one of the following: (a) there is no flame and no glowing (no ignition) or (b) burning or glowing time is less than 30 s after removal of the glow wire and cotton under the specimen does not ignite; GWIT is a temperature 25°C higher than the maximum temperature of the glow wire tip which does not ignite the material. Glow Wire Test Apparatus suitable for lighting equipment, low voltage electric appliance and electrician instruments such as electrical and electronic products.

Standards
IEC 60695-2-10:2013, IEC 60695-2-11, IEC 60695-2-12,IEC 60950-1, IEC 60238, IEC 60745-1, IEC 60400, IEC 60730-1, IEC 60598-1, IEC 61050, IEC 60335-1, IEC 61058-1, IEC 60742, IEC 60669-1,IEC 60884, IEC 60320, VDE 0620, GB 2099, DIN VDE 0471 Teil 2-4-0, BS 1361, IEC 60829, UL 746A, BS EN 60695-2-1, BS 6458, NF C20-921-1,IS:11000, ASTM D 6194-03…

Specifications

Glow Wire Element 4mm diam (77% Ni/20±1 % Cr)
Temperature Range 50ºC ~1100 °C± 2 °C continuous adjustable
Temperature Resolution 1ºC
Searing Time 0~999.9 s  ± 0.1 s, adjustable
(usually selected for 30s)
Light-off  Time 0~999.9 s  ± 0.1 s, adjustable
Fireouttime 0~999.9 s  ± 0.1 s, adjustable
Current Range 0 to 200 A
Thermocouple Type K (Ni/Cr - Ni/Al),1.0 mm diam
Traverse Unit Horizontal
Force 0.95N±0.1N
Maximum Travel 13 cms
Test Travel Limit 7 mm, adjustable
Flame Height Indicator 30 cm
Test Background black background, 20Lx
Studio Volume 0.5 cubic, other volume can be customized
Exhaust air-bleed hole,100mm diam
Input Power 250 VAC 50/60Hz 3A, 115 VAC optional

 灼熱絲試驗儀使用注意事項 http://www.cestr.com/cn/support/show.asp?id=45
The Glow-wire Tester use matters needing attention to: http://www.cestr.com/en/support/show.asp?id=45
IEC60695-2-10:2013灼熱絲試驗儀新標準修改內容和要求:http://www.cestr.com/cn/news/show.asp?id=241

IEC60695-2-10:2013 Update and modify the requirementshttp://www.cestr.com/cn/news/show.asp?id=241

日本新电安法要求插头增加漏电起痕和灼热丝试验要求http://www.cestr.com/cn/news/show.asp?id=260

特供JWDS0028日标漏电起痕试验陶瓷片和纤维纸http://www.cestr.com/cn/news/show.asp?id=48

JWDS0028日标漏电起痕试验仪(高精度) http://www.cestr.com/cn/product/show.asp?id=212;

IEC60112/GB4207/ JIS C 2134标准-RH-5012漏电起痕试验仪http://www.cestr.com/cn/product/show.asp?id=185;

IEC 60695-2-10/GB/T5169.10-2006标准-RH-5014灼热丝试验仪http://www.cestr.com/cn/product/show.asp?id=186;

IEC 60695-2-10:2013最新版对灼热丝材质有新的要求http://www.cestr.com/cn/news/show.asp?id=241;

IEC 60695-2-10:2013灼热丝标准 http://www.cestr.com/cn/news/show.asp?id=219.

    [ Previous: RH-5018 Electrical indicator, RH-5021 Test Finger-nail(B type/11 type),GB16842/IEC61032 ]
    [ Next: RH-5012 Tracking Tester,PTI/CTI(IEC60695,IEC60112(GB 4207),IEC60335-1, IEC60598-1, JIS C2134) ]