Conform to the standard
The test machine is designed according to IEC 60884-1 article 24, VDE 0620-1 article 24, GB 2099.1-1 article 24, IS1293 article 24, AS/NZS 3112 article 2.13.13.6, BS 1363-1 article 12 and other relevant technical requirements.
Scope of application
Wear test is carried out on the insulating sheath layer specially used for AC plug terminal (insert piece).
Technical parameters
1. Counting range: 0 ~ 999999 times of digital display, which can be preset;
Part 2, blow grind: U friction needle diameter: Φ 1 mm;
3, friction Angle: 10 °.
4. Weight: 4N (the total weight of the inserted tip that is pressed and rubbed);
5. Friction stroke: 9mm;
6. Friction speed: 15 times/min (30 one-way/min);
7. Working power supply: AC 220V, 50Hz/60Hz