Home > Technical Support > Solutions > UL62-2011电线型号含义,线号,芯线,绝缘护套平均最小厚度,额定温度,电流,电压要求UL 62Cordage Type, Construction,Cype Designation and Rating,Conductor Jacket & Insulation Material and Min. Average Thickness
UL62-2011电线型号含义,线号,芯线,绝缘护套平均最小厚度,额定温度,电流,电压要求UL 62Cordage Type, Construction,Cype Designation and Rating,Conductor Jacket & Insulation Material and Min. Average Thickness
UL62-2011电线型号含义,线号,芯线,绝缘护套平均最小厚度,额定温度,电流,电压要求UL 62Cordage Type, Construction,Cype Designation and Rating,Conductor Jacket & Insulation Material and Min. Average Thickness
UL Cordage Type, Construction and Rating/UL62电线型号 , 结构和额定要求
Cord Type*
型号
AWG
Size Range
线号
No. of Cond.
导体 / 芯线
Conductor Insulation Material and Min. Average Thickness (inches) 导体绝缘材料最小平均厚度 ( 英寸 )
Jacket Material and Min. Average Thickness**
(inches) 护套材料最小平均厚度 ( 英寸 )
Temperature Rating (°C)† 额定温度
Voltage Rating
额定电压
Standard
标准
Other
其它
HPN
18 – 12
2 or 3††
.045 Rubber
90
105
300
HSJ
18 – 12
2, 3, 4
.030 Rubber††
.030 Rubber
90
300
HSJO
18 – 12
2, 3, 4
.030 Rubber ▲
.030 Oil-Resistant Rubber
90
300
S
18 – 2
2 or more
.030 Rubber ▲
.060 Rubber ▲
60
75, 90
600
SE
18 – 2
2 or more
.030 lastomer
.060 lastomer
105
600
SEO
18 – 2
2 or more
.030 lastomer
.060 lastomer
105
600
SJ
18 – 10
2, 3, 4
.030 Rubber ◆
.030 Rubber
60
75, 90
300
SJE
18 – 10
2, 3, 4, 5
.030 Elastomer††
.030 Elastomer
105
300
SJEO
18 – 10
2, 3, 4, 5
.030 Elastomer
.030 Elastomer
105
300
SJO
18 – 10
2, 3, 4
.030 Rubber ◆
.030 Oil-Resistant Rubber
60
75, 90, 105
300
SJT
18 – 10
2, 3, 4
.030 Plastic ◆
.030 Plastic
60
75, 90, 105
300
SJTO
18 – 10
2, 3, 4
.030 Plastic ◆
.030 Plastic
60
75, 90, 105
300
SO
18 – 2
2 or more
.030 Rubber ▲
.060 Oil-Resistant Rubber ▲
60
75, 90
600
SP-1
18
2 or 3††
.030 Rubber
60
300
SP-2
18 – 16
2 or 3††
.045 Rubber
60
300
SP-3
18 – 12
2 or 3††
.060 Rubber ▲
60
300
SPT-1
18
2 or 3††
.030 Plastic
60
75, 90, 105
300
SPT-2
18 – 16
2 or 3††
.045 Plastic
60
75, 90, 105
300
SPT-3
18 – 10
2 or 3††
.060 Plastic ▲
60
75, 90, 105
300
ST
18 – 2
2 or more
.030 Plastic ▲
.060 Plastic ▲
60
75, 90, 105
600
STO
18 – 2
2 or more
.030 Plastic ▲
.060 Plastic ▲
60
75, 90, 105
600
SV
18
2 or 3††
.015 Rubber
.030 Rubber
60
75, 90
300
SVE
18 – 17
2 or 3††
.015 Elastomer
.030 Elastomer
105
300
SVEO
18 – 17
2 or 3††
.015 Elastomer
.030 Elastomer
105
300
SVO
18
2 or 3††
.015 Rubber
.030 Oil-Resistant Rubber
60
75, 90
300
SVT
18 – 17
2 or 3††
.015 Plastic
.030 Plastic
60
75, 90, 105
300
SVTO
18 – 17
2 or 3††
.015 Plastic
.030 Plastic
60
75, 90, 105
300
TPT
27 (Tinsel)
2
.030 Plastic
60
250
TST
27 (Tinsel)
2
.015 Plastic
.030 Rubber
60
125
* Types SVO, SVTO, SJO, SJTO, SO, STO and HSJO have jackets which are also recognized for oil resistance at maximum temperature of 60ºC. Types SJ, SJO, SJT, SJTO, S, SO, ST and STO may also be made for outdoor use and will be indicated by adding a “W” suffix to the cord type. Similarly, types SJ, SJTO, SJO, SJT, S, SO, ST and STO may also be made in water-resistant grades with “Water-Resistant” printed on the jacket. 3-wire SJT may be made in special low-leakage constructions for medical equipment cords.
** Where no jacket is shown, the construction is integral or flat style with insulation also serving as jacket.
† For cordage ratings higher than 60ºC, the temperature limit is printed on the outside of the jacket. This does not apply to heater cordage type HPN, rated 90ºC, or 105ºC.
†† Recognized in three conductors when third or center conductor (with Green or Green/Yellow stripe) is used for equipment grounding.
▲ Insulation and jacket thickness depend on cordage size. Thickness as shown are for 18 and 16 AWG.
◆ Insulation and jacket thickness depend on cordage size.
No. 12 AWG requires .030" conductor insulation thickness and .045" jacket thickness. No. 10 AWG requires .045" conductor insulation thickness and .060" jacket thickness.
The term Elastomer refers to thermoplastic elastomer.
Inner Conductor Colors/内导体(绝缘)颜色
Function/ 功能
North American (NA) 北美
International (ICC)/ 国际
Hot/ 火线
Black
Brown
Neutral/ 中线
White
Blue
Ampere Ratings of 3-Conductor Bulk Flexible Cords and Cables/3芯软线及电缆容许额定电流
Table below shows the amperes a cord or cable can carry continuously wthout exceeding its temperature rating and is for two current carrying conductors and one non-current carrying conductor. (Taken from the National Electric Code)
Conduct or Size AWG
Types SE, SEO, SJE, SJEO, SJT, SJTO, ST, STO, SPT-1, SPT-2, SPT-3(AMPS/ 安倍 )
18
10A
16
13A
14
18A
12
25A
10
25A
10
30A
8
40A
6
55A
4
70A
2
95A
UL Cordage Type Designation/UL62电线型号含义
UL Cordage Type
Designation
HPN
HSJ
HSJO
S
SE
SEO
SEOO
SJ
SJE
SJEO
SJEOO
SJO
SJOO
SJT
SJTO
SJTOO
SO
SOO
SP-1
SP-2
SP-3
SPE-1
SPE-2
SPE-3
SPT-1
SPT-2
SPT-3
ST
STO
STOO
SV
SVE
SVEO
SVEOO
SVO
SVOO
SVT
SVTO
SVTOO
TPT
TST
XT
Heater Parallel Neoprene
Heater Service Junior
HSJ with Oil-Resistant Jacket
Service
Service Elastomer
SE with Oil-Resistant Jacket
SEO with Oil-Resistant Insulation
Service Junior
Service Junior Elastomer
SJE with Oil-Resistant Jacket
SJEO with Oil-Resistant Insulation
SJ with Oil-Resistant Jacket
SJO with Oil-Resistant Insulation
Service Junior Thermoplastic
SJT with Oil-Resistant Jacket
SJTO with Oil-Resistant Insulation
Service with Oil-Resistant Jacket
SO with Oil-Resistant Insulation
Service Parallel — 1/32 ″ Insulation
Service Parallel — 3/64 ″ Insulation
Service Parallel — 1/16 ″ Insulation
Service Parallel Elastomer — 1/32 ″ Insulation
Service Parallel Elastomer — 3/64 ″ Insulation
Service Parallel Elastomer — 1/16 ″ Insulation
Service Parallel Thermoplastic — 1/32 ″ Insulation
Service Parallel Thermoplastic — 3/64 ″ Insulation
Service Parallel Thermoplastic — 1/16 ″ Insulation
Service Thermoplastic
ST with Oil-Resistant Jacket
STO with Oil-Resistant Insulation
Service Vacuum
Service Vacuum Elastomer
SVE with Oil-Resistant Jacket
SVEO with Oil-Resistant Insulation
SV with Oil-Resistant Jacket
SVO with Oil-Resistant Insulation
Service Vacuum Thermoplastic
SVT with Oil-Resistant Jacket
SVTO with Oil-Resistant Insulation
Tinsel Parallel Thermoplastic
Tinsel Service Thermoplastic
Christmas Tree Thermoplastic
NOTE: Service parallel types—wall thickness for integral construction.
Elastomer is a thermoplastic material with elastomeric properties similar to rubber.