PRH-202B Cord Extension Comprehensive Tester
|
COMPLIANCE & KEYWORDS
|
RH-202B Cord Extension Comprehensive Tester (Power Plug Integrated Tester, Multiple Socket-outlet Tester) is designed and manufactured in compliance with IEC/EN60884-1 , 60320-1, 60799 , EN50075, DIN VDE 0620-1, 0625-1, BS 1363-1, 546, 4573, 4491-1, SEV 1011, SEV 6533, 6534, SI 32, CEI 23-50; UL498, UL817, CSA C22.2; GB1002, 2099.1, 17465.1, 15934, JIS C8303, 8306, CNS 10917-2, IS 1293, KS C8305, TIS 166-2549, GOST R51322.1, MS 589, SS145/A, 472, SB107-2-D1 , CS 0017, NBR 14136, 6147, AS/NZS 3112, 3109.1, IRAM 2063, 2073, SABS 164-1, 60799, etc. And suitable for electrical testing items of power cord with connector and without connector, two core wire and three core wire and so on.
|
TECHNICAL SPECIFICATION
|
Main Technical Data
|
Describe
|
This is general version specification, the various types has the slightly different.
|
Input Power
|
220VAC+/-10%,50Hz/60Hz, 5A
|
Input pressure
|
≤4Kgf/cm²
|
Master control system
|
PLC and the man-machine dialogue touch screen microcomputer control
|
Test the power cord types
|
Can test with/without polarity plugs and connectors (1 P, 2 P, 1 P + 2 P),
can also defer to the customer request design.
|
Test Items
|
Polarity and continuity test, insulation resistance, interpolar HI-pot
and tegument HI-pot, leakage current, relative length (Grounding resistance and so on can be customizable).
|
Test modes
|
The pedal switch control or insert the test sample for automatic test.
|
Test sequence
|
Polarity, continuity(open and short circuit),
insulation resistance, interpolar HI-pot and tegument HI-pot.
|
Continuity &
Polarity test
|
Test principle
|
1、Inductive test wire length≥10pF
2、Loop modes: polarity click give out sound and light signals instructions, dislocation has audio and light alarm prompt, need to press the reset button to stop.
|
Test result modes
|
1、Continuity is NG, indicator can't achieve qualified point, give out sound and light alarm.
2、The other is NG, automatic locking and has sound and light alarm prompt, need to manually reset button.
3、Qualified products and unqualified automatically counting, passed automatic unlocking push out and print qualified marks.
|
Hi-pot Test
|
Inside output voltage
|
0~5KV Continuous adjustable
|
Inside output Hi-pot
leakage current
|
According to the modes choose 0.5, 1.0, 2.0, 3.0, 5.0mA
or 0.5~10 mA continuous adjustable.
|
Outside output voltage
|
0~5KVContinuous adjustable
|
Outside output Hi-pot
leakage current
|
According to the modes choose 0.5, 1.0, 2.0, 3.0, 5.0mA
or 0.5~10 mA continuous adjustable.
|
Rated power
|
600VA
|
Waveform
|
50/60Hz,AC sine wave
|
Voltage calibration
|
+/-5%
|
Switch
|
Zero-level conversion
|
Test time
|
Digital display, preset type, inside and outside Hi-pot can be arbitrarily set.
|
High pressure indicator
|
Proportion
|
1:50
|
Class
|
1.5 Class
|
Judgment precision
|
+/-3% Present setting values
|
High pressure fail judgment
|
Judging
|
Measured value larger than the basic value;
The cut-off output voltage and give out the fail signal.
|
Leakage current value
|
According to the modes choose 0.5, 1.0, 2.0, 3.0, 5.0mA
or 0.5 ~ 10 mA continuous adjustable.
|
Judgment precision
|
+/-3% Present setting values
|
Calibration
|
Pure resistance loading series connection R M S, true value table test.
|
Insulation resistance
|
Output voltage
|
500V DC
|
Voltage calibration
|
+/-5%
|
Reference value setting
|
5 MΩ/100MΩ,Customizable
|
Judging
|
Measured value smaller than the basic value and give out the fail signal.
|
Judgment precision
|
+/-5%
|
Indicator
|
(0-100 MΩ)+/-5%
|
Measurement range
|
0~∞
|
Insulation testing body
|
Conductive sponge
|
Relative length
|
Wire sensitivity
|
Inductive test wire length≥10pF
|
Thimble
|
Test qualified marks
|
Has ordinary push out and heats up push out two modes,
temperature can be set, print a test qualified marks.
|
Tally function
|
Automatic counter
|
Qualified products and unqualified automatically counting.
|
Safety protection
|
Electric shock protection
|
The earth grounding protection, safeguards the personal safety,
The machine has installed, only need grounding.
|
Size
|
Machine size
|
According to various types
|
Other
|
special requirements
|
1、Can be install unqualified automatic destroying cutting knife.2、According to demand choose a variety of plug and connector test special socket。3、Other functions can be custom installed.
|
|
CALIBRATION CERTIFICATES
|
All testing equipment and instrument before they leave the company, we will be in accordance with the relevant standard to carry on detection and calibration and issue certificate of quality. Also on behalf of clients to third-party calibration organization for calibration, the calibration and detection data can be traced back to national and international standards, and obtains with CNAS signed the multilateral agreements of mutual recognition of national and regional accreditation laboratory organizations mutual recognition, issued by the certificate and reports by the other members of the ILAC-MRA has been recognized and accepted, fully meet ISO9000 quality system and safety bodies and so on requirements. But calibration costs are not included in the price.
|
OTHER CONDITIONS
|
Support and service by E-mail: cestr@cestr.com; jeremyho88@163.com
Welcome letter from you and willing to help and listen to your feedback.
|
|