Rh-109e single-head simplex plug power line comprehensive test machine (cross test)
In the cross-test mode, the left and right test stations can be cross-tested (only in the inductive mode, polarity cannot be detected).
In normal test mode, just like normal test machine.
The pitfalls of inductive testing are:
1. Tail short circuit cannot be detected reliably
2. Non-polarity check
Functions and features
The test items
Can test single head, 2,3 core product polarity, conduction, insulation, external pressure, pressure between the poles, with progressive detection, defective clamping alarm function.
Test mode
1) single head and two cores without polarity
2) non-polarity of single head and two core points
3) single head and two cores have polarity
4) single head and three cores without polarity
5) single head and three cores have polarity
Insulation voltage DC500V
Insulation resistance 5 m Ω, 100 m Ω transfinite alarm function
Leakage current setting (mA) 0 ~ 20mA adjustable, accuracy 5%, special circuit design, minimize the internal leakage of the machine, improve the test accuracy.
Interelectrode high voltage 0 ~ 5.0kvac, accuracy 5%, ultra high voltage setting.
External pressure 0 ~ 5.0kvac, accuracy 5%, ultra high pressure setting (copper exposure test more reliable).
Pressure test time 0 ~ 999.9s
Control mode microcomputer (PLC)+ color touch screen setting
Test parameter lock password lock
Other functions have the function of intelligent prompt for the occurrence of adverse events; The test circuit has strong anti-interference ability and the test is more reliable.
Power supply voltage 220VAC 5%/50Hz/5A
The air source pressure is about 0.4mpa. The air source is stable and free from impurities. The whole machine leaves the factory without air pressure device.
|