Home > Product > Environment Test Equipment > Rh-4015 IEC aging chamber
 
 

Product Name:Rh-4015 IEC aging chamber

Product category:Environment Test Equipment

Product Description

Product features

1. Scientific air inlet and exhaust holes ensure that gravity (natural) convection can achieve uniform temperature in the cabinet;

2. Adopt international quality brand electrical appliances and comprehensive safety protection functions (leakage circuit breaker protection, over-current circuit breaker, short-circuit insurance, electronic over-temperature protection, motor overheating and other comprehensive safety protection) to ensure

You can use it safely for a long time;

3, unique structure design, box surface temperature is low, reduce, avoid scald; More humanized high design, convenient to use the personnel to take and put the test products.

Main parameters:

Performance Performance

Circulation method enforces Forced convection air Circulation

Temperature range Temp. The range R.T + 20 ℃ ~ 200 ℃

Temperature fluctuation degree of Temp. Fluctuation < + / - 1 ℃

The temperature deviation Temp. Variation < 4 ℃ (< 80 ℃)

Heat up time 90min

The Ventilation speed is 20 times per hour

Turntable rotation speed 9r/min

Constitute the Components

Bladder material Interior material SUS304 Stainless steel plate Stainless steel SUS304

Exterior material cold - rolled steel plate is sprayed with powder

Insulation Heat insulating material Glass wool Glass wool

Sealing of door is an environment-friendly silicone rubber strip

Exhaust port diameter 50mm 1(back)50mm I.D. 1(the back side)

The Iron-chrome wire Heater with nichrome Heater

Controller is the Controller

Temperature control Temp. The control method of microcomputer PID control PlD control by microprocessor

Temperature setting methods Temp. Setting method by Δ del set Digital Digital setting by key

Measuring and setting temperature LCD Digital display by LCD

Fixed temperature Operation

Heater circuit control SCR

Temperature Sensor Temp. Sensor PT100 Ω

Work time control Max9999 hours

Safe Device

Over current protection, Leakage circuit Breaker, Over temperature prevention etc.

Specifications and Standard

Internal dimensions 400 600 480mm (D W H)

External dimensions 650 940 1250mm (D W H)

Internal capacity: 115L

Single phase AV220V/50HZ Power supply AV220V/50HZ

Power Approx 2.0KW

The Accessories Accessories

Revolving shelf,1set, Revolving shelf,1set/Product description 1set

Execute and meet the Test Standard

GB/ T 11026.4-1999(idt iec60216-4-1:1990); ASTM D5423-93 (Reapproved 1999); GB 2099.1-2008 (IEC 60884.1); DIN VDE 0620-1-2010 (iec 884-1); DIN EN 60309-1 (VDE 0623 Teil 1)

Optional Accessories

Programmable temperature controller/increase shelf/Cable hole Φ 50 / RS485 communication interface designed temp., controller/Additional shelf plate/Cable hole (50 mm)/External communication terminal (RS485), etc.