1. Test speed: 1 / SEC
2. The residence time: 0-99.99 S
3.The number Location: six locations
4. Drive way: step motor + synchronous belt transmission
5. Wire and twist length: 10 cm
6. Test the wire diameter: OD1 ~ 10 mm
7. Jordan farmar weight: 4.5 Lb 6 x
8. Work cycle method:
The origin began to turn to the left four laps, stay for 4 s
Turn right again 4 circle back to the origin, the 4 s
Then turn right four laps from the source, stay for 4 s
Turn left again 4 circle back to the origin, the 4 s
9. Residence time is, the circle number, and also can be made
10. Touch screen/LED display, parameter Settings intuitive convenient (optional)
11. Installation dimensions: 1000 mmx1017mmx500mm