BS EN 50525-1:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U0/U) PART 1: GENERAL REQUIREMENTS(DIN EN 50525-1:2011/ VDE 0285-525-1)
BS EN 50525-2-31-2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U0/U) PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-2-72-2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U0/U) PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-2-11-2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U0/U) PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50395-2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS EN 50396-2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
举例: 以H03VV-F为例,需要进行的额外测试有:
cold impact at -5C( 旧标准为-15C) 增加non-compatibity test非兼容测试 (旧标准没有此要求, 只有compatibity test)bending test, voltage test (2000V) after bending test(旧标准在bending test后没有voltage test 的要求)
--------------------------------------------------------------------------------------
DIN EN 50525-2-11 H03VV(H2)-F
Cold impact test at -5 °C
new: non-compatibility test
DIN EN 50525-2-11 H05VV(H2)-F
Cold impact test at -5 °C
new: H05VVH2-F 2 X 1,5
DIN EN 50525-2-11 H03V2V2(H2)-F
Cold impact test at -5 °C
new: non-compatibility test
DIN EN 50525-2-11 H05V2V2(H2)-F
Cold impact test at -5 °C
new: H05V2V2H2-F 2 X 1,5
DIN EN 50525-2-11 H05V2V2D3-F
Cold impact test at -5 °C
For all types: Voltage test after bending test with 2000 V
--------------------------------------------------------------------------------------
DIN EN 50525-2-12 H03VV(H2)H8-F
Cold impact test at -5 °C
new: non-compatibility test
New requirements for the marking after coiling
DIN EN 50525-2-12 H05VV(H2)H8-F
Cold impact test at -5 °C
New requirements for the marking after coiling
DIN EN 50525-2-21 H05RR-F
new: cold bending test for the insulation at -35 °C
DIN EN 50525-2-21 H05RN-F
new: cold bending test for the insulation at -35 °C
new: H05RN-F 4 x 0,75 and H05RN-F 4 x 1
DIN EN 50525-2-21 H07RN-F, H07RN-F vieladrig
new: cold bending test for the insulation at -35 °C
DIN EN 50525-2-21 H07RN8-F
new: cold bending test for the insulation at -35 °C
DIN EN 50525-2-21 H05BQ-F
no changes
DIN EN 50525-2-21 H07BQ-F
no changes
DIN EN 50525-2-21 H05GG(H2)-F
no changes
DIN EN 50525-2-21 H05BB-F
no changes
DIN EN 50525-2-21 H07BB-F
no changes
DIN ENDIN EN 50525-2-21 H05BN4-F
no relevant changes
DIN EN 50525-2-21 H07BN4-F, H07BN4-F multi core
no relevant changes
--------------------------------------------------------------------------------------
DIN EN 50525-2-22 H03RT-H
no changes
H05RR-H und H03V4V4-H withdrawn
--------------------------------------------------------------------------------------
DIN EN 50525-2-31 H05V-U/-R/-K
new: Cold impact test at -5 °C
DIN EN 50525-2-31 H07V-U/-R/-K
Cold impact test at -5 °C (new: -K)
DIN EN 50525-2-31 H05V2-U/-R/-K
new: Cold impact test at -5 °C
DIN EN 50525-2-31 H07V2-U/-R/-K
Cold impact test at -5 °C (new: -K)
--------------------------------------------------------------------------------------
DIN EN 50525-2-41 H05S-U/-K
no changes
DIN EN 50525-2-41 H03S-K
no changes
DIN EN 50525-2-41 H05SJ-U/-K
no changes
DIN ENDIN EN 50525-2-41 H05SS-K
no changes
--------------------------------------------------------------------------------------
DIN EN 50525-2-42 H07G-U/-R/-K
Cold impact test at -5 °C
DIN EN 50525-2-42 H05G-U/-K
Cold impact test at -5 °C
--------------------------------------------------------------------------------------
DIN EN 50525-2-51 H05VV5-F
The cable shall be marked with the code designation ``H05VV5-F``
Cold impact test at -5 °C
DIN EN 50525-2-51 H05VVC4V5-K
The cable shall be marked with the code designation ``H05VVC4V5-K``
Cold impact test at -5 °C
changed calculation procedure for cables which number of cores does not belong to the preferred ones
--------------------------------------------------------------------------------------
DIN EN 50525-2-71 H03VH-Y
new: Cold impact test at -5 °C
--------------------------------------------------------------------------------------
DIN EN 50525-2-72 H03VH7H-F
Cold impact test at -5 °C
--------------------------------------------------------------------------------------
DIN EN 50525-2-81 H01N2-D/E
extension to 240 mm2
DIN EN 50525-2-82 H03RN-F
new: Cold bending test for the insulation at -35 °C
DIN EN 50525-2-82 H05RN(H2)-F
new: Cold bending test for the insulation at -35 °C
--------------------------------------------------------------------------------------
DIN EN 50525-2-83 H05SS-F; H05SST-F
The insulation shall be a single layer
DIN EN 50525-2-83 H05SSD3-K; H05SSD3T-K
The insulation shall be a single layer
--------------------------------------------------------------------------------------
DIN EN 50525-3-11 H03Z1Z1(H2)-F
Cold impact test at -5 °C
DIN EN 50525-3-11 H05Z1Z1(H2)-F
Cold impact test at -5 °C
Voltage test after bending test with 2000 V
--------------------------------------------------------------------------------------
DIN EN 50525-3-21 H07ZZ-F
new temperature for compatibility test: 7 d at 100 ± 2 °C (old: 80 ± 2 °C)
--------------------------------------------------------------------------------------
DIN EN 50525-3-31 H07Z1-U/-R
Cold impact test at -5 °C
DIN EN 50525-3-31 H07Z1-K
Cold impact test at -5 °C
DIN EN 50525-3-31 H07Z1-U/-R
Cold impact test at -5 °
DIN EN 50525-3-31 H07Z1-K
Cold impact test at -5 °C
--------------------------------------------------------------------------------------
DIN EN 50525-3-41 H07Z-U/-R
no changes
DIN EN 50525-3-41 H07Z-K
no changes
DIN EN 50525-3-41 H05Z-U
no changes
DIN EN 50525-3-41 H05Z-K
no changes
|